BIOMEDICAL OEM MODULE

MTL System Pte Ltd offers OEM modules and sensors, which can be adjusted according to the exact individual custom specifications. The adaption of special developed OEM modules and sensors to your existing product portfolio is possible. On request we will customize the OEM modules and sensors. If you need any project development please feel free to contact us.

We have the following Standard Biomedical Module for your projects (Please click on the link for more details) :

 

 

 

etC02Sidestream System - CAP100 :  CAP100 is a module for measuring and monitoring the end tidal CO2 concentration or the CO2 partial pressure of the respiratory gas and respiration rate. It records the capnogram in the sidestream mode.     
 

End tidal CO2 sensor module


 

  • Bi-directional serial port
  • Transfer of capnogram every 40ms
  • Transfer of etCO2 and respiration rate every second
  • Automatic temprature and pressure compensation
  • Adjustable flow
  • Nitrous oxide gas compensation
  • Boot flash for software updates
  • Integrated CPU
  • Download Operational Manual
  • Download Brochure



Sensor module for fast oxygen measurement - EROS : For side- or mainstream electrochemical oxygen measurement of inspired or expired O2 concentrations. EROS consists of an oxygen sensor and a digital logic board attached to it. The sensor has in connection with the module a very low response time: from air to pure oxygen t90=122sec only.  The module consists of Oxygen sensor and a digital board attached to the sensor.
 

Fast Oxygen Measurement Module

  • Digital logic on board
  • Reliable numeric results and real tiime wave form
  • Using electrochemical sensor technology for price effective development
  • Maintenace friendly
  • Low power consumption  



Measurement of Breathing Gas Flow - SpiroQuant - MA : For anaesthesia machines with anaemoneter sensor SpiroQuant A. The module drives the hot-wire flow sensor SpiroQuant A and generates a signal proportional to the actual flow dependent power consumption of the heated wire. Using a calibration curve, this value can be converted into the actual flow valve.
 

Breathing Gas Flow Sensor Module
 



Measurement of Breathing Gas Flow - SpiroQuant - MH : For anaesthesia machines with flow-pressure transducer. The module works with flow pressure transducer sensors and is compatible with SpiroQuant H flow sensor. The sensor signal is conditioned with a precision differential pressure sensor and a 16 bit A/D converter. The module is equipped with two 3/2-way valves for determining the "zero level" of the pressure sensor.
 

Breathing Gas Flow Sensor Module
 

 



 

SPO2 Pulse Oximeter Module - ChipOx : ChipOx is a pulse oximeter module for the non-invasive determination of the functional oxygen saturation in human arterial blood and for measuring the pulse frequency. ChipOx can be installed as an OEM module in medical products or other applications for humans or veterinary purposes.
The module suppresses artifacts for the most partwith various algorithms, and indicates when they are too high.

SPO2 ChipOX Module
 

  • Maintenance or recalibration free
  • Low energy consumption
  • Warning and error reporting system
  • Freely configurable, analog inputs
  • Multiplexed analog output
  • Serial interface for data exchange
  • Additional digital I/O functions
  • Easy implementation
  • Small dimensions (31 x 4 x 5mm)
  • Download Brochure
  • Download User Manual

 


SPO2 Pulse Oximeter Module ChipOx Developement Kit The Development Kit is for testing ChipOx®. It offers the possibility to immediately put ChipOx® into operation in connection with the associated PC software, and to test it.
 

Click to view details
Click for details

  ChipOX Developement Kit Cnsists of :

  • ChipOx Module
  • SpO2 Finger-clip sensor large
  • PC Software
  • RS232 adapter



NIBP2010 Non-Invasive Blood Pressure OEM Module : NIBP2010 for economical and reliable Non invasive Blood pressure measurement from adults to Neonates. EnviteC offers proven technology for mobile to intensive care applications.

Non-Invasive Blood Pressure OEM Module

 


NIBP2010 + ChipOx, Non-Invasive Blood Pressure with ChipOx Module : The NIBP2010 OEM modules was designed  to adapt the micro SpO2 Module ChipOx on-top.

Click to see details
Click for details

 

 


EMI12 - 12 Channels ECG Module :  is a miniaturized module for the simple integration of a 12-channel ECG in diagnostic systems. The device has an open communication
protocol and can be easily integrated in all devices, such as electrocardiographs or patient monitors. For the simple integration in embedded systems, the EMI12 has a standard UART, USB and RS232 interface.

12 Channels ECG module